In today's rapid economic development, the research results on boilers are more and more advanced. In the actual operation of the boiler, it is restricted by many practical factors. Oxidation Resistant Chain Boiler Grate is a kind of layer-fired furnace with a high degree of mechanization. It is a furnace type widely used in industrial boilers. Most of the capacity is 10-130t/h, and a small part has a small capacity of 1-2t. It is used in boilers.

Before installation, the size of the foundation must be checked according to the foundation drawing. Check the straightness of the side panel before installing the Oxidation Resistant Chain Boiler Grate side panel. If a bend is found, it should be straightened. Under the side plate, use a long, 200mm×180mm iron plate as a backing plate to adjust the elevation of the grate side plate (generally, the number of backing plates is not more than 4, and several groups of backing plates are placed under each grate side plate as required; backing plates It should be placed on the embedded iron of the foundation and directly under the web of the side plate of the grate). Check the horizontality above the beam, check the diagonal of the two sides of the board, after adjustment, the data of the above test must be within the specified range. After the adjustment is completed, the backing plate group is welded into one body with the foundation iron plate and the lower movable plate of the grate side plate. Grout filling between the backing plate group and the backing plate group. The ash release device should be flatly installed on the Z-shaped steel of the lower guide rail, and the joint between the bottom plate and the bottom plate should be sealed well. After the air duct is installed, the valve limit and pull rod should be installed. , the pull rod push-pull valve should be flexible. After connecting the air supply duct to the side plate of the Oxidation Resistant Chain Boiler Grate, connect the ash release lever to the ash dragging device in the air supply duct, and adjust the position so that the ash release valve can slide easily and flexibly; The plate should rotate flexibly; there should be no jamming phenomenon; the interface between the pull rod, the air regulating plate and the air supply pipe should be well sealed to reduce air leakage.

During the operation, the faults of the Oxidation Resistant Chain Boiler Grate should be discovered and solved in time, but in order to ensure the work efficiency. More should start with the prevention of failures, improve the operation level of combustion technology, repair and maintain equipment, and do regular maintenance work to ensure better operation of the chain grate.